En
Email
  • host cell dna residue detection kit
  • host cell dna residue detection kit

BlueGene Biotech MDCK Host Cell DNA Residue Detection Kit-100T

CK-D100T MDCK Host Cell DNA Residue Detection Kit

The MDCK Host Cell DNA Residue Detection Kit can be used for Quantitative analysis of DNA residue in recombinant protein expressed products, purified intermediate and finished products from host cell.

Products

Specifications of MDCK Host Cell DNA Residue Detection Kit

Introduction

This kit utilizes the TaqMan probe-based fluorescence quantitative PCR (qPCR) method. By employing highly specific primers and probes, it offers exceptional specificity and sensitivity, with a limit of quantification (LOQ) as low as 3 fg/μL. The kit is fully compatible with our Magnetic Residual DNA Sample Preparation Kit (Cat# CG-DP050 or CG-DP100), enabling seamless integration into your workflow.

The preparation process of DNA Control is completely consistent with that of the National Standard reference of host cell DNA y; therefore, it has high purity and no protein or ion interference. DNA Control has been calibrated by National Standard to ensure the accuracy of the sample quantitative detection.

The kit provides DNA Dilution Buffer, which enables good replicate parallelism in a single experiment and good reproducibility between multiple experiments.



Kit Components

DNA Amplification

Components NO.

Components Name

Cat#/Size CK-D050T(50T)

B1

2XqPCR Mix

1.25mL

B2

Primer&Probe Mix

200μL

B3

DNA Dilution Buffer

4×1.5mL

B4

DNA Control (30ng/μL)

50μL

B5

RNase-Free H2O

1mL

B6

50X ROX Reference Dye(Optional)

0.3ml


Shipping and Storage

1All components are shipped on dry ice.
2

The kit should be stored at -20℃ and it is recommended to be used within one year. The component of B2 should be stored protected from light.



PCR Reaction System on MDCK Host Cell DNA Residue Detection Kit


Components

Volume(μL)

2XqPCR Mix

12.5

Primer&Probe Mix

2

DNA template (control or sample)

5

Add water

5.5

Total Volume

25


  • Mix solution = (number of reaction wells+4) * (12.5+2+5.5) μL (including the volume lost in the 4 wells).


  • The detection range of the standard curve mentioned above is suitable for most experiments and can be adjusted as needed, such as 30fg/μL to 300pg/μL.

Criteria for Results

  • Standard Curve: R ²> 0.99; Amplification Efficiency: 90% ≤ Eff% ≤ 110%; Slope: -3.8~-3.1.


  • The recovery rate of spiked samples=(measured value of spiked samples - measured value of samples)/theoretical value of spiked samples * 100%, with a range of 50% -150%.


  • Negative Quality Control (NC): The reaction system contains only DNA Dilution Buffer, and the detection result should have a Ct value greater than the mean Ct value of the lowest concentration Ct on the standard curve.


  • No Template Control (NTC): Replace only the DNA template with DNA Dilution Buffer in the reaction system, and the Ct value obtained should be 'Undetermined' or ≥35.


Quality Control on MDCK Host Cell DNA Residue Detection Kit

Accuracy (Standard: ≦30%)

Intra Variation% 

Inter Variation%

Recovery


Limit of Quantitation

Specificity

-


BlueGene Biotech Product Show

Related Bluegene Biotech Products

Join us and become BlueGene's distributor, you will get a broad range of Life science research products and more than 12 years of experienced technical supports.