En
Email
  • bovine serum albumin elisa 1
  • bovine serum albumin elisa 1

BlueGene Biotech Mouse Oxytocin ELISA kit

  • Neuroscience

E03O0023 Mouse Oxytocin ELISA kit

The Mouse Oxytocin ELISA kit can be used to identify samples from the mouse species. Oxytocin can also be called Pitocin, Syntocinon, OT.

Specifications of Mouse Oxytocin ELISA kit

Product Information

Cat. No.

E03O0023

Product Name

Mouse Oxytocin ELISA kit

Species

Mouse

Product Size

48 Tests / 96 Tests

Concentration

50-1000pg/ml

Sensitivity

1.0pg/ml

Principal

Competitive ELISA

Sample Volume

100 ul

Sample Type

Serum, plasma, cell culture supernatants, body fluid and tissue homogenate

Assay Time

90 minutes

Platform

Microplate Reader

Conjugate

HRP

Detection Method

Colorimetric

Storage

2-8°C


Kit Components

MATERIALS

SPECIFICATION

QUANTITY

MICROTITER PLATE

96 wells

stripwell

ENZYME CONJUGATE

6.0 mL

1 vial

STANDARD A (0.5mL)

0 pg/ml1 vial

STANDARD B (0.5mL)

50 pg/ml

1 vial

STANDARD C (0.5mL)

100 pg/ml

1 vial

STANDARD D (0.5mL)

250 pg/ml

1 vial

STANDARD E (0.5mL)

500 pg/ml

1 vial

STANDARD F (0.5mL)

1000 pg/ml

1 vial

SUBSTRATE A

6 mL

1 vial

SUBSTRATE B

6 mL

1 vial

STOP SOLUTION

6 mL

1 vial

WASH SOLUTION (100 x)

10 mL

1 vial

BALANCE SOLUTION

3 mL

1 vial


Principle of the Assay

OT ELISA kit applies the competitive enzyme immunoassay technique utilizing an anti-OT antibody and an OT-HRP conjugate. The assay sample and buffer are incubated together with OT-HRP conjugate in pre-coated plate for one hour. After the incubation period, the wells are decanted and washed five times. The wells are then incubated with a substrate for HRP enzyme. The product of the enzyme-substrate reaction forms a blue colored complex. Finally, a stop solution is added to stop the reaction, which will then turn the solution yellow. The intensity of color is measured spectrophotometrically at 450nm in a microplate reader. The intensity of the color is inversely proportional to the OT concentration since OT from samples and OT-HRP conjugate compete for the anti-OT antibody binding site. Since the number of sites is limited, as more sites are occupied by OT from the sample, fewer sites are left to bind OT-HRP conjugate. A standard curve is plotted relating the intensity of the color (O.D.) to the concentration of standards. The OT concentration in each sample is interpolated from this standard curve. 


Quality Control on Mouse Oxytocin ELISA kit

Coefficient of Variance

Intra Variation% <10%

Inter Variation% <12%

Recovery

95-102%

Linearity

Diluent Ratio

Range %

1:2

93-105

1:4

88-106

1:8

86-108

Specificity/Cross-reactivity

No significant cross-reactivity or interference between OT and analogues was observed.


BlueGene Biotech Product Show

Summary of the Assay Procedure for Mouse Oxytocin ELISA kit

Summary of the Assay Procedure for Mouse Oxytocin ELISA kit

Citations of Mouse Oxytocin ELISA kit

E03O0023 has been referenced in the below publications:

Studies of pharmacodynamic material basis of Eucommia ulmoides Oliv.


Related Bluegene Biotech Products

Join us and become BlueGene's distributor, you will get a broad range of Life science research products and more than 12 years of experienced technical supports.