Mouse Angiotensin 2 ELISA kit is suitable for the detection of samples from mouse species. Angiotensin 2 can also be called as Alpha 1 antiproteinase, antitrypsin; Ang II; ANG III; Angiotensin I; Angiotensin II; Angiotensin III; Angiotensinogen; AT-2; AT-II.
Specifications Of E03A0204 Mouse ANG2 ELISA Kit
Porduct's Information | |
Cat.NO. | E03A0204 |
Porduct's Name | Mouse Angiotensin 2 ELISA kit |
Species | Mouse |
Product Size | 48 Tests / 96 Tests |
Concentration | 50-1000 pg/mL |
Sensitivity | 1.0 pg/mL |
Principal | Competitive ELISA |
Sample Volume | 100 ul |
Sample Type | Serum, plasma, cell culture supernatants, body fluid and tissue homogenate |
Assay Time | 90 minutes |
Platform | Microplate Reader |
Conjugate | HRP |
Detection Method | Colorimetric |
Storage | 2-8°C |
Kit Components | ||
MATERIALS | SPECIFICATION | QUANTITY |
MICROTITER PLATE | 96 wells | stripwell |
ENZYME CONJUGATE | 6.0 mL | 1 vial |
STANDARD A (0.5mL) | 0 pg/mL | 1 vial |
STANDARD B (0.5mL) | 50 pg/mL | 1 vial |
STANDARD C (0.5mL) | 100 pg/mL | 1 vial |
STANDARD D (0.5mL) | 250 pg/mL | 1 vial |
STANDARD E (0.5mL) | 500 pg/mL | 1 vial |
STANDARD F (0.5mL) | 1000 pg/mL | 1 vial |
SUBSTRATE A | 6 mL | 1 vial |
SUBSTRATE B | 6 mL | 1 vial |
STOP SOLUTION | 6 mL | 1 vial |
WASH SOLUTION (100 x) | 10 mL | 1 vial |
BALANCE SOLUTION | 3 mL | 1 vial |
Principle of the Assay |
ANG2 ELISA kit applies the competitive enzyme immunoassay technique utilizing an anti-ANG2 antibody and an ANG2-HRP conjugate. The assay sample and buffer are incubated together with ANG2-HRP conjugate in pre-coated plate for one hour. After the incubation period, the wells are decanted and washed five times. The wells are then incubated with a substrate for HRP enzyme. The product of the enzyme-substrate reaction forms a blue colored complex. Finally, a stop solution is added to stop the reaction, which will then turn the solution yellow. The intensity of color is measured spectrophotometrically at 450nm in a microplate reader. The intensity of the color is inversely proportional to the ANG2 concentration since ANG2 from samples and ANG2-HRP conjugate compete for the anti-ANG2 antibody binding site. Since the number of sites is limited, as more sites are occupied by ANG2 from the sample, fewer sites are left to bind ANG2-HRP conjugate. A standard curve is plotted relating the intensity of the color (O.D.) to the concentration of standards. The ANG2 concentration in each sample is interpolated from this standard curve. |
Quality Control On Mouse ANG2 ELISA Kit
CV | Intra Variation% <10% | |
Inter Variation% <12% | ||
Recovery% | 92-114 | |
Linearity | Diluent ratio | Range % |
1:2 | 96-108 | |
1:4 | 93-102 | |
1:8 | 93-104 | |
Specificity/ Cross-reactivity | No significant cross-reactivity or interference between ANG2 and analogues was observed. |
BlueGene Biotech Product Show
Summary Of The Assay Procedures For E03A0204 Mouse ANG2 ELISA Kit

Citations Of Mouse Angiotensin 2 ELISA Kit
Neutrophil-Endothelial Interactions Mediate Angiopoietin-2-Associated Pulmonary Endothelial Cell Dysfunction in Indirect Acute Lung Injury in Mice
Product: E03A0201 Mouse Angiotensin 1 ELISA kit;