Rat Epinephrine/Adrenaline ELISA kit is suitable for the detection of samples from Rat species. Epinephrine/Adrenaline can also be called as ADR; EPI.
Specifications of E02A0007 Rat EPI ELISA Kit
Porduct's Information | |
Cat.NO. | E02A0007 |
Porduct's Name | Rat Epinephrine/Adrenaline ELISA kit |
Species | Rat |
Product Size | 48 Tests / 96 Tests |
Concentration | 100-2500pg/ml |
Sensitivity | 1.0 pg/mL |
Principal | Competitive ELISA |
Sample Volume | 100 ul |
Sample Type | Serum, plasma, cell culture supernatants, body fluid and tissue homogenate |
Assay Time | 90 minutes |
Platform | Microplate Reader |
Conjugate | HRP |
Detection Method | Colorimetric |
Storage | 2-8°C |
Kit Components | ||
MATERIALS | SPECIFICATION | QUANTITY |
MICROTITER PLATE | 96 wells | stripwell |
ENZYME CONJUGATE | 6.0 mL | 1 vial |
STANDARD A (0.5mL) | 0 pg/mL | 1 vial |
STANDARD B (0.5mL) | 100 pg/mL | 1 vial |
STANDARD C (0.5mL) | 250 pg/mL | 1 vial |
STANDARD D (0.5mL) | 500 pg/mL | 1 vial |
STANDARD E (0.5mL) | 1000 pg/mL | 1 vial |
STANDARD F (0.5mL) | 2500 pg/mL | 1 vial |
SUBSTRATE A | 6 mL | 1 vial |
SUBSTRATE B | 6 mL | 1 vial |
STOP SOLUTION | 6 mL | 1 vial |
WASH SOLUTION (100 x) | 10 mL | 1 vial |
BALANCE SOLUTION | 3 mL | 1 vial |
Principle of the Assay |
EPI ELISA kit applies the competitive enzyme immunoassay technique utilizing an anti-EPI antibody and an EPI-HRP conjugate. The assay sample and buffer are incubated together with EPI-HRP conjugate in pre-coated plate for one hour. After the incubation period, the wells are decanted and washed five times. The wells are then incubated with a substrate for HRP enzyme. The product of the enzyme-substrate reaction forms a blue colored complex. Finally, a stop solution is added to stop the reaction, which will then turn the solution yellow. The intensity of color is measured spectrophotometrically at 450nm in a microplate reader. The intensity of the color is inversely proportional to the EPI concentration since EPI from samples and EPI-HRP conjugate compete for the anti-EPI antibody binding site. Since the number of sites is limited, as more sites are occupied by EPI from the sample, fewer sites are left to bind EPI-HRP conjugate. A standard curve is plotted relating the intensity of the color (O.D.) to the concentration of standards. The EPI concentration in each sample is interpolated from this standard curve. |
Quality Control On Rat EPI ELISA Kit
CV | Intra Variation% <10% | |
Inter Variation% <12% | ||
Recovery% | 94-109 | |
Linearity | Diluent ratio | Range % |
1:2 | 95-104 | |
1:4 | 93-106 | |
1:8 | 90-110 | |
Specificity/ Cross-reactivity | No significant cross-reactivity or interference between EPI and analogues was observed. |
BlueGene Biotech Product Show
Summary of The Assay Procedures For E02A0007 Rat EPI ELISA Kit

Citations of Rat Epinephrine/Adrenaline ELISA Kit
Role of plateau hypoxia hypothermia complex damage to the vascular endothelial cells and the protective effect
Product:
E02N0013 Rat Noradrenaline ELISA kit;
E02E0182 Rat Total Endothelin ELISA kit;
E02H0061Rat Hypoxia Inducible Factor 1, Alpha ELISA kit;
E02V0010 Rat Vascular Endothelial Growth Factor ELISA kit
The mechanism research of neurons injury in the basolateral of amygdala induced by stress
Product:
E02A0038 Rat Adenosine Triphosphate ELISA kit;
E02N0013 Rat Noradrenaline ELISA kit;