En
Email
  • bovine serum albumin elisa 1
  • bovine serum albumin elisa 1

BlueGene Biotech Human 8-Isoprostane ELISA kit

E01I0770 Human 8-Isoprostane ELISA kit

The Human 8-Isoprostane ELISA kit can be used to identify samples from the human species. 8-Isoprostane can also be called 8-iso-PGF2α.

Specifications of Human 8-Isoprostane ELISA kit

Product Information

Cat. No.

E01I0770

Product Name

Human 8-Isoprostane ELISA kit

Species

Human

Product Size

48 Tests / 96 Tests

Concentration

50-1000 pg/ml

Sensitivity

1.0 pg/ml

Principal

Competitive ELISA

Sample Volume

100 ul

Sample Type

Serum, plasma, cell culture supernatants, body fluid and tissue homogenate

Assay Time

90 minutes

Platform

Microplate Reader

Conjugate

HRP

Detection Method

Colorimetric

Storage

2-8°C


Kit Components

MATERIALS

SPECIFICATION

QUANTITY

MICROTITER PLATE

96 wells

stripwell

ENZYME CONJUGATE

6.0 mL

1 vial

STANDARD A (0.5mL)

0 pg/mL

1 vial

STANDARD B (0.5mL)

50 pg/mL

1 vial

STANDARD C (0.5mL)

100 pg/mL

1 vial

STANDARD D (0.5mL)

250 pg/mL

1 vial

STANDARD E (0.5mL)

500 pg/mL

1 vial

STANDARD F (0.5mL)

1000 pg/mL

1 vial

SUBSTRATE A

6 mL

1 vial

SUBSTRATE B

6 mL

1 vial

STOP SOLUTION

6 mL

1 vial

WASH SOLUTION (100 x)

10 mL

1 vial

BALANCE SOLUTION

3 mL

1 vial


Principle of the Assay

8-iso-PGF 2α ELISA kit uses an anti-8-iso-PGF 2α antibody and an 8-iso-PGF 2α-HRP conjugate in a competitive enzyme immunoassay method. 8-iso-PGF 2α-HRP conjugate is incubated with the assay sample and buffer in a pre-coated plate for one hour. The wells are decanted and washed five times when the incubation period is over. The HRP enzyme substrate is then incubated in the wells. The result of the enzyme-substrate reaction is a complex that is blue in hue. The process is finally stopped by adding a stop solution, causing the solution to turn yellow. In a microplate reader, the color intensity is measured spectrophotometrically at 450 nm. Due to competition for the anti-8-iso-PGF 2α antibody binding site between 8-iso-PGF 2α from samples and 8-iso-PGF 2α-HRP conjugate, the intensity of the color is inversely proportional to the concentration of 8-iso-PGF 2α. Since the number of sites is limited, as more sites are occupied by 8-iso-PGF 2α from the sample, fewer sites are left to bind 8-iso-PGF 2α-HRP conjugate. A standard curve is plotted relating the intensity of the color (O.D.) to the concentration of standards. The 8-iso-PGF 2α concentration in each sample is interpolated from this standard curve.


Quality Control on Human 8-Isoprostane ELISA kit

Coefficient of Variance

Intra Variation% <10%

Inter Variation% <12%

Recovery

95-102%

Linearity

Diluent Ratio

Range %

1:2

93-105

1:4

88-106

1:8

86-108

Specificity/Cross-reactivity

No significant cross-reactivity or interference between 8-iso-PGF 2α and analogues was observed.


BlueGene Biotech Product Show

Summary of the Assay Procedure for Human 8-Isoprostane ELISA kit

Summary of the Assay Procedure for Human 8-Isoprostane ELISA kit

Citations of Human 8-Isoprostane ELISA kit

E01I0770 has been referenced in the below publications:

Oxidative stress and antioxidant status in women with gestational diabetes mellitus diagnosed by IADPSG criteria.

Related Bluegene Biotech Products

Join us and become BlueGene's distributor, you will get a broad range of Life science research products and more than 12 years of experienced technical supports.