BlueGene Biotech Mouse Transferrin Receptor ELISA kit

E03T0137 Mouse Transferrin Receptor ELISA kit

The Mouse Transferrin Receptor ELISA kit can be used to identify samples from the mouse species. Transferrin Receptor can also be called TFR, CD71, TFR1, P90, TFRC, T9, Trfr, sTfR, Transferrin receptor protein 1.

Specifications of Mouse Transferrin Receptor ELISA kit

Product Information

Cat. No.

E03T0137

Product Name

Mouse Transferrin Receptor ELISA kit

Species

Mouse

Product Size

48 Tests / 96 Tests

Concentration

2.5-50ng/ml

Sensitivity

0.1ng/ml

Principal

Competitive ELISA

Sample Volume

100 ul

Sample Type

Serum, plasma, cell culture supernatants, body fluid and tissue homogenate

Assay Time

90 minutes

Platform

Microplate Reader

Conjugate

HRP

Detection Method

Colorimetric

Storage

2-8°C


Kit Components

MATERIALS

SPECIFICATION

QUANTITY

MICROTITER PLATE

96 wells

stripwell

ENZYME CONJUGATE

6.0 mL

1 vial

STANDARD A (0.5mL)

0 ng/ml1 vial

STANDARD B (0.5mL)

2.5 ng/ml

1 vial

STANDARD C (0.5mL)

5.0 ng/ml

1 vial

STANDARD D (0.5mL)

10 ng/ml

1 vial

STANDARD E (0.5mL)

25 ng/ml

1 vial

STANDARD F (0.5mL)

50 ng/ml

1 vial

SUBSTRATE A

6 mL

1 vial

SUBSTRATE B

6 mL

1 vial

STOP SOLUTION

6 mL

1 vial

WASH SOLUTION (100 x)

10 mL

1 vial

BALANCE SOLUTION

3 mL

1 vial


Principle of the Assay

TFR ELISA kit applies the competitive enzyme immunoassay technique utilizing an anti-TFR antibody and an TFR-HRP conjugate. The assay sample and buffer are incubated together with TFR-HRP conjugate in pre-coated plate for one hour. After the incubation period, the wells are decanted and washed five times. The wells are then incubated with a substrate for HRP enzyme. The product of the enzyme-substrate reaction forms a blue colored complex. Finally, a stop solution is added to stop the reaction, which will then turn the solution yellow. The intensity of color is measured spectrophotometrically at 450nm in a microplate reader. The intensity of the color is inversely proportional to the TFR concentration since TFR from samples and TFR-HRP conjugate compete for the anti-TFR antibody binding site. Since the number of sites is limited, as more sites are occupied by TFR from the sample, fewer sites are left to bind TFR-HRP conjugate. A standard curve is plotted relating the intensity of the color (O.D.) to the concentration of standards. The TFR concentration in each sample is interpolated from this standard curve. 


Quality Control on Mouse Transferrin Receptor ELISA kit

Coefficient of Variance

Intra Variation% <10%

Inter Variation% <12%

Recovery

95-102%

Linearity

Diluent Ratio

Range %

1:2

93-105

1:4

88-106

1:8

86-108

Specificity/Cross-reactivity

No significant cross-reactivity or interference between TFR and analogues was observed.


BlueGene Biotech Product Show

Summary of the Assay Procedure for Mouse Transferrin Receptor ELISA kit

Summary of the Assay Procedure for Mouse Transferrin Receptor ELISA kit

Citations of Mouse Transferrin Receptor ELISA kit

E03T0137 has been referenced in the below publications:

Hydroxyurea Could Be a Good Clinically Relevant Iron Chelator.

The role of HFE genotype in macrophage phenotype.

Study on the regulation and mechanism that Mycobacterium Tuberculosis reacts at the iron metabolism of infected Mouse Alveolar macrophages.